Satin finish extruded sheet in a range of colours for areas requiring a decorative appearance. Also suitable where sheet may come into contact with food.
Extruded semi-rigid PVCu sheet.
Colour:
Surface finish:
Thickness:
Size:
Weight:
Maximum service temp:
26 Satin colours
Satin
2.5mm
2500 x 1220mm (W136)
3000 x 1220mm (W137)
3.6 kg/m²
60°C
Altro Whiterock W136/137 PVCu extruded sheet is supplied with a protective film on its face which can be left in place until the room is ready for use. This also helps to protect the surface from dust while other trades are in the area. It is ideal for applications requiring a hygienic easy-to-clean, almost maintenance free wall finish, which conforms to European hygiene requirements.
The sheets can be fixed directly to most dry substrates depending on its surface suitability, using one of the following methods:
Cutting to be carried out using a fine tooth circular saw with TCT cutting blades and pressure guide, fine tooth blade jigsaw, a fine tooth handsaw, a high speed TCT router.
- see relevant detailed drawings
- see relevant detailed drawings, available on the Altro Website; www.altro.com
Altro Whiterock is normally thermoformed on-site, internal and external corners including window and door reveals are neatly clad, omitting the need for corner trims. However, profiles are available for these junctions if the need arises. Vulnerable external corners are usually over-clad with stainless steel corner protectors, to a height of 1200mm.
Regular cleaning using a soft cloth and a suitably diluted mild detergent is all that is normally required. Stubborn marks can be removed with Altro Cleaner A859 or nonabrasive domestic type cream bath cleaner.
Do not use abrasive pads or wire wool. Do not clean above 60°C. Cleaning cards are available on request.
Resistant to a wide range of chemicals, specific details on request.
Ex-stock.
Sheets should be stored flat, fully supported and left for 24 hours to attain the ambient room temperature prior to installation (min 14°C).
Altro Whiterock W136/137 has a maximum working temperature of 60°C. For temperatures above this use stainless steel. Stainless steel must be used for all open flame areas (available cut to size) and must be extended to min 300m past heatsource. If a layout showing the position of equipment can be supplied, we will provide specific advice as to the best combination of materials to use.
Our Technical Services Department is available for advice on 01462 707600.
Property | Standard | Value |
---|---|---|
Surface finish | Satin | |
Thickness | 2.5mm | |
Size | 2500 mm x 1220 mm 3000 mm x 1220 mm |
|
Weight | 3600 g/m² | |
Density | ISO 1183 | 1.44 g/cm3 |
Maximum service temperature | 60℃ | |
Hardness (Shore D) | ISO 868 | 76 |
Fire resistance | EN 13501-1 BS 476 pt 6 BS 476 pt 7 |
B- s3, d0 Class 0 (when fixed to a non-combustible substrate) Class 1 |
Notched Impact resistance | ISO 179/1ea | 9.5 KJ/m² |
Impact resistance | ISO 179/1eU | +20℃ without breakage 0℃ without breakage -20℃ without breakage |
Flexural strength | ISO 178 | 70 MPa |
Tensile strength | ISO 527 | 52 MPa |
E-modulus of elasticity | ISO 527 | 2950 MPa |
Compressive strength | DIN 53421 | 68 N/mm² |
Vicat softening point VST/B | ISO 306 | 73℃ |
Expansion coefficient | DIN 53752 | 0.07 mm/mK |
Heat distortion temperature | ISO 75-2 | 60℃ |
Water Absorption | ISO 62 | ≤ 0.1% |
Thermal Conductivity | EN 12524 | 0.17 W/mK |
″U″ value (bonded to 100mm block wall) | DIN 52612 | 1.8 W/m² ℃ |
Moisture Vapour Transmission rate (MVTR) | ASTM E96 | ≤ 0.12g/m²/24hrs |
Water vapour resistivity | ASTM E96 | 3.82 x 105GN.S/Kg.m |
NOTE: “Altro Ltd” (“Altro”) endeavours to ensure that advice and information given in Product Data Sheets, Method Statements and Material Safety Data Sheets (all known as Product Literature) is accurate and correct. However, where Altro has no control over the selection of its products for particular applications, it is important that any prospective customer, user or specifier, satisfies him / herself that the product is suitable for the intended application. In this process, due regard should be taken of the nature and composition of the background / base and the ambient conditions both at the time of laying / applying / installing / curing of the material and when the completed work is to be brought into use.
However, as site conditions and the execution of the work are beyond our control, we accept no resultant liability.
Altro’s policy is one of continuous research and development and we reserve the right to update our products and information at any time without prior notice.