Can't see the region you're looking for? You can find a list of our global locations here
| Property | Standard | Performance |
| Flooring Type | EN 651 | Resilient safety flooring |
| Thickness | EN ISO 24346 | 2.85 mm |
| Wear layer thickness | EN ISO 24340 | 0.7mm |
| Roll dimensions | EN ISO 24341 | 2.0m x 20.00m - 40m² |
| Weight | EN ISO 23997 | 2.6 kg/m² |
| Classification for use | EN ISO 10874 | 34 / 42 |
| Fire performance | EN 13501-1 EN ISO 9239-1 EN ISO 11925-2 |
Class Cfl-s1 ≥ 4.5kW/m² Pass |
| Slip resistance | EN 16165 Annex C / PTV Slider 96 EN 13845 Annex C EN 13893 EN 16165 Annex B / ASR A1.5 (formerly DIN 51130) |
≥ 36 ESf ≥ 0.30 / DS R10 |
| Flexibility | EN ISO 24344 | Pass |
| Light fastness | EN ISO 105-B02 | ≥ 6 |
| Wear resistance | EN 13845 Annex D | ≤ 10% particles lost over 50000 cycles |
| Castor chair abrasion | ISO 4918 | Pass |
| Residual indentation | EN ISO 24343-1 | ≤ 0.20mm |
| Sound insulation | ISO 10140-3 | Ca. 14dB |
| Chemical resistance | EN ISO 26987 | Good |
| Under floor heating | EN 12524 | Suitable 27°C at adhesive line |
| Electrical behaviours | EN 1815 | ≤2kV Antistatic |
| VOC Emission | CDPH 1350/ Floorscore / M1 | Approved |